Solar panels on a Washington, DC rowhouse roof
solar energy

How to Check Your Solar Savings Against Actual Performance

Key Takeaway

Keep a solar forecast you can audit. Compare matching production records, Pepco bills and certificate statements to identify why actual savings differ.

— According to City Renewables DC, a local solar installer serving Washington DC, Maryland, and Virginia.

Keep the forecast you can check after installation

To test whether a DC solar system is delivering the savings you expected, keep the original production forecast and compare it with monitoring records and actual bills for matching periods. Record electricity production separately from bill savings and certificate income. A shortfall in one does not explain the others.

Before signing, ask for a downloadable monthly production forecast, its design assumptions and the financial worksheet behind the savings estimate. After installation, use those same documents as your baseline. Keep an unchanged copy so a later forecast revision does not replace what you were originally shown.

The DC Office of the Attorney General's solar consumer alert ↗ recommends getting total costs and projected savings in writing before signing. That written record also gives you a starting point for a useful performance conversation later.

Build a record that separates energy from money

Create a folder for the signed proposal, system design, utility approval, monitoring exports and Pepco bills. Keep financing statements and any certificate-sale statements in separate sections. Record when the system began operating and any periods when monitoring or equipment was unavailable.

For each comparison period, put the forecast production beside the measured production. Match the dates as closely as the records allow. If the monitoring export uses calendar months while the bill uses a different billing cycle, mark that mismatch instead of treating the totals as directly comparable.

Keep a note of changes in the household: an electric vehicle, new heating equipment, occupancy changes or an extended absence. Ask the installer to explain how those changes affect the original savings comparison. Do not revise the saved original forecast; document the new assumptions alongside it.

Read a production shortfall in context

A forecast based on typical weather is an estimate, rather than a promise about a particular year. PVWatts results documentation ↗ explains that its typical-year estimates can differ from a particular month's actual output by as much as ±30%, and annual output by as much as ±10%.

Those published ranges describe variability in that modeling context. They do not establish a performance guarantee or a universal threshold for deciding that equipment is working correctly. Ask which weather data and assumptions your own proposal used, and which contractual terms apply if output falls short.

If a monitoring record shows a gap, first ask whether it reflects missing data or missing generation. Save screenshots and exports, then request an explanation from the responsible installer or monitoring provider. Avoid diagnosing equipment from a bill alone, and leave electrical inspection and repairs to qualified professionals.

Reconcile the savings calculation separately

Once the production record is clear, compare the financial worksheet with the actual statements. Ask which bill lines the forecast expected to reduce, what electricity prices it assumed and how it treated charges that remain. Use the tariff and account information applicable to your own Pepco service.

PVWatts explains why an energy estimate alone is insufficient to establish financial value: electricity consumption and rate details also matter. See the current tool documentation ↗. A useful savings review therefore needs the bill and the forecast assumptions, rather than only the solar app's production total.

Keep certificate income separate from utility bill savings. Compare the sale statements with the price and fees assumed in the financial worksheet. Keep loan or lease payments visible in their own column. Ask the provider to explain each difference using the underlying records, rather than combining all the figures into an unexplained savings total.

Ask for an explanation you can follow

Send the relevant forecast, monitoring export and bill with a concise description of the discrepancy. State the dates, the figures being compared and any known changes in household use. Request a written explanation of whether the difference comes from production, weather assumptions, electricity use, rate assumptions or missing records.

If a contract includes a production guarantee, follow its notice process and deadlines. A forecast and an enforceable guarantee are separate documents; use the actual agreement to understand any remedy.

Before choosing an installer, ask how you will obtain monitoring records and who handles performance questions. Confirm that answer in the written offer. For a project discussion, bring your bills and the proposal worksheet to a Green Zone assessment, and ask which assumptions can be documented for later review.